How much R-value do you need?
R-value measures resistance to heat flow: double it and you halve the heat passing through. The US Department of Energy’s recommended attic levels by climate zone — the targets built into the selector above — are:
| Climate zone | Example areas | Recommended attic R-value |
|---|---|---|
| 1 | South Florida, Hawaii | R-30 to R-49 |
| 2 | Gulf Coast, central Florida | R-30 to R-60 |
| 3 | Southern states, coastal California | R-30 to R-60 |
| 4 | Mid-Atlantic, Pacific Northwest coast | R-38 to R-60 |
| 5 | New England, Great Lakes, mountains | R-49 to R-60 |
| 6–8 | Northern tier, Alaska | R-49 to R-60 |
The selector uses a sensible mid-to-upper target per zone; local building code minimums for new work are lower in the warm zones, and there is little penalty beyond cost for aiming high in an attic, where depth is usually free. Walls are a different story — cavity depth caps what fits — so this calculator is framed for attics and other open spaces where depth is yours to choose.
From R-value to depth and bags
Every material delivers R-value at its own rate per inch, so the depth you need is added R ÷ R-per-inch. Targeting R-38 of new insulation: cellulose at 3.5 per inch needs 10.86 inches; blown fiberglass at 2.5 needs 15.2 inches; closed-cell spray foam at 6.5 needs just 5.85 inches — the reason foam owns the tight spaces. Existing insulation counts: an attic with R-19 of old batts in a Zone 4 home needs only R-30 more to reach R-49, about 8.6 inches of cellulose blown over the top.
For blown cellulose the calculator also counts bags, using the standard coverage of roughly 24.3 sq ft per 30 lb bag at R-19, scaled by the R you are adding: 1,000 sq ft to R-38 from scratch takes 83 bags. Buy a few percent extra — coverage charts assume perfect even blowing, and the last corner of every attic is deeper than you think. Blown materials also settle: cellulose loses roughly 10–20% of its installed depth over the first years, which is why installers blow to the settled-depth figure on the bag chart rather than the target straight off. Rulers stapled to the trusses every few feet are how you prove the depth while you work.
Air sealing: the step that makes insulation work
Insulation slows heat conducted through the ceiling; it does nothing about warm air leaking through gaps — and in most houses the leaks matter as much. Before adding insulation, seal the penetrations: around pipes, wires, recessed lights (with rated covers), the attic hatch, and the top plates of interior walls. Fiberglass in particular underperforms badly with air moving through it. Also keep ventilation paths open: baffles at the eaves hold the insulation back from the soffit vents so the roof can breathe, and bathroom fans should duct outside, never into the attic. None of this changes the arithmetic above, but it decides whether the R-value you paid for is the R-value you get — an R-49 attic with an unsealed hatch and open chases can perform closer to R-30.
Frequently asked questions
How many bags of insulation do I need for 1,000 square feet?
For blown cellulose, about 42 bags (30 lb) to reach R-19 and about 83 bags to reach R-38 over 1,000 sq ft, using the standard coverage of roughly 24.3 sq ft per bag at R-19 and scaling by R-value. If you are topping up existing insulation, count only the R you are adding — going from R-19 to R-49 (adding R-30) over 1,000 sq ft takes about 65 bags. Other blown materials publish their own bag charts; check the bag in the store against the depth this calculator gives you.
How thick should attic insulation be?
It depends on the material, because thickness is just R-value divided by R-per-inch. For the common Zone 4–5 target of R-49: blown cellulose about 14 inches, fiberglass batts about 15–16 inches (usually two layers), blown fiberglass about 19–20 inches, closed-cell spray foam about 7.5 inches. In warm Zones 1–3 the R-30 to R-38 targets trim those depths by roughly a third. Measure what you have first — an existing 6 inches of fiberglass batt is about R-19 already banked.
Can I put new insulation over old insulation?
Yes — topping up is the normal approach, and the R-values simply add. Old batts in decent condition can stay; blow or lay the new layer over them, running new batts perpendicular to the old to cover the joist tops. Three cautions: do not stack a second vapour barrier (use unfaced batts on top), do not bury knob-and-tube wiring or non-rated recessed lights (an electrician’s call), and fix any roof leak or mould first — insulation hides problems better than it solves them.
What is the difference between R-value and U-value?
They are reciprocals: U = 1 ÷ R. R-value describes a material or assembly’s resistance to heat flow (higher is better) and is the number on insulation packaging in the US. U-value describes how readily a whole assembly — window, wall, roof — transmits heat (lower is better) and is the figure used in most of the rest of the world and for windows everywhere. An R-49 attic assembly has a U-value of about 0.02; a single-glazed window sits near U 5.6, which is R-0.18 — a hole in the blanket by comparison.
Is spray foam worth it versus blown insulation?
On R-per-inch, closed-cell foam (about 6.5) doubles cellulose (about 3.5) and nearly triples blown fiberglass — decisive where depth is limited, like a cathedral ceiling. Foam also air-seals as it insulates. The counterweights are cost (typically several times more per R per square foot, professionally installed), the need for proper ventilation during application, and that in a deep open attic the cheaper materials reach the same R-value for far less money. The usual verdict: foam where space is tight or air sealing is the problem, blown material where depth is free.
Related tools
Figures checked on 24 November 2026. Everything is calculated in your browser — nothing you type is sent anywhere.