BTU Calculator
A rule of thumb that knows it is one
Every quick BTU method starts from floor area times a climate factor — for cooling, about 20 BTU per square foot in a moderate climate, 15 in a cool one, up to 35 where summers are fierce — and then adjusts for the room's realities: ceiling height scales the air volume, poor insulation adds 15%, heavy sun adds 10%, each person past the second adds about 600 BTU of body heat, and a kitchen adds roughly 4,000 for its appliances. The worked example lands at 15,100 BTU: a 300-square-foot living space in a hot climate starts at 9,000, the sun takes it to 9,900, four occupants to 11,100, and the kitchen finishes the job — about 1.26 tons of cooling, pointing at a 15,000 or 18,000 BTU unit. Hold the result at arm's length in one specific way: this is a sizing estimate of the kind used to shortlist equipment, and the HVAC industry's real method (a Manual J load calculation, which models your actual walls, windows, orientation and local design temperatures) is what a contractor should run before a whole-house system is bought. For a single room unit, the rule of thumb is the tool the job actually uses.
Why oversizing is a defect, not a luxury
The instinct to buy one size up is the most expensive mistake in cooling. An oversized air conditioner satisfies the thermostat in short bursts and switches off — and a unit that short-cycles never runs long enough to wring the humidity out of the air, leaving the room cool and clammy, which occupants answer by lowering the thermostat further and paying more to feel worse. It also wears its compressor with starts, the hardest thing a compressor does. Undersizing fails more honestly, running flat-out and falling behind on the hottest afternoons. The sizing target is therefore a match, not a maximum — and for heating the same logic softens only slightly, since a furnace or heat pump modestly oversized loses efficiency rather than comfort. When the calculator's figure falls between two unit sizes, the tiebreakers are humidity (choose smaller in a damp climate) and genuine extremes (choose larger only if heatwaves routinely exceed the design assumptions).
Frequently asked questions
How many BTU do I need for a 300 sq ft room?
In a moderate climate, about 6,000 BTU before adjustments — 300 square feet at the standard 20 BTU per square foot — and realistically 7,000 to 9,000 once sun, occupants and ceiling height are counted. In a hot climate the same room starts at 9,000 and the worked example on this page, a sunny kitchen-living space with four people, reaches 15,100. That spread is the honest answer to the question as asked: square footage sets the base, but climate roughly doubles it between a coastal and a desert city, and no single number survives contact with an actual room. Put your own room's facts in above and use the figure it returns.
What is a ton of cooling?
Twelve thousand BTU per hour — the rate at which a ton of ice melting over a day absorbs heat, which is where the unit comes from and why it survives in an industry that otherwise runs on BTU. Residential systems are sold in half-ton steps from about 1.5 to 5 tons. The conversion matters because equipment is labelled both ways: the worked example's 15,100 BTU is 1.26 tons, so it sits between the 1-ton (12,000 BTU) and 1.5-ton (18,000 BTU) sizes, and the page's oversizing discussion is what decides between them. For a single room, stay in BTU — window and split units are rarely sold by the ton.
Why is my new air conditioner making the room clammy?
Most likely it is oversized — the failure mode this page warns about. Cooling air and drying air are two jobs: the drying happens as moisture condenses on the cold coil over time, and it needs run time. A unit too powerful for the space drops the temperature to the thermostat setting in minutes and stops, having barely dehumidified at all; the room feels cold and damp simultaneously, and mould risk climbs quietly. Fixes in order of cost: run the fan mode correctly, check the unit is not a size or two above the load (the calculator above gives the load), use a standalone dehumidifier in shoulder seasons, and at replacement time, size to the calculation rather than to the old unit — which may itself have been the oversized mistake, faithfully copied.
Does ceiling height really change the BTU needed?
Yes, in proportion — the unit conditions a volume of air, not a floor plan. The standard factors assume an 8-foot ceiling; a 10-foot ceiling holds 25% more air and this calculator scales by height over 8, so the same room needs roughly a quarter more capacity, and a double-height space needs close to double the naive figure. Vaulted ceilings add a second effect the simple scaling understates: hot air pools at the peak in summer, which a ceiling fan pushing down genuinely mitigates. If your room has a sloped ceiling, use its average height — the volume is what counts, not the peak.
Is this accurate enough to buy a whole-house system on?
No — and it does not pretend to be. This is the industry-recognised rule of thumb, good for room units, shortlists and sanity-checking a quote. A whole-house system should be sized by a Manual J load calculation, which models your construction, window areas and orientations, duct losses and your town's actual design temperatures; a contractor who sizes by square footage alone, or by matching the old unit, is skipping the step that decides whether the system will dehumidify, cycle and last. Use this page to walk into that conversation knowing roughly what the answer should be — if a quote lands wildly above the figure your room produces here, the right response is to ask for the Manual J, not to argue about the rule of thumb.