Battery Runtime Calculator

In short: a 12V 100Ah battery holds 1,200 watt-hours on paper — but a lead-acid battery should only give up half of that, and the inverter wastes another slice. Through an 85 percent inverter, a 200W load gets 2.55 hours, not the 6 the headline capacity suggests. Enter your battery and load and this page does the honest version of the sum.

The runtime formula, honestly applied

Runtime (hours) = volts x amp-hours x usable fraction x inverter efficiency / load watts. Each term earns its place. Volts x amp-hours is the stored energy in watt-hours: 12 x 100 = 1,200 Wh. The usable fraction is the term marketing leaves out: a lead-acid battery discharged to empty is a battery being destroyed, and 50 percent depth of discharge is the standard planning limit for a reasonable cycle life; lithium iron phosphate tolerates 90 percent routinely, which is a large part of why a lithium battery of the same headline capacity runs a load nearly twice as long. Inverter efficiency — typically 85 to 92 percent for a decent unit — is the toll for turning DC into AC; a pure DC load skips it, so set the efficiency to 100 if there is no inverter.

Series and parallel wiring change the inputs, not the formula. Two 12V 100Ah batteries in parallel are 12V 200Ah; in series they are 24V 100Ah — both store the same 2,400 Wh, and the runtime is the same once you enter the bank's voltage and capacity as wired. What changes is current and cable losses, which is why larger systems run at 24 or 48 volts.

Why real runtime comes in below the calculation

This formula is the planning figure, and three effects shave it in practice. Peukert's law: a lead-acid battery's rated capacity is measured at a gentle 20-hour discharge rate, and drawing it faster yields less total energy — at a 1-hour rate a lead-acid battery may deliver only half its rated amp-hours, so heavy loads on lead-acid run noticeably shorter than the formula says. Lithium barely suffers this effect. Age and temperature shave more: a battery at 0 degrees C can lose 20 percent of its capacity until it warms, and every battery fades with years and cycles. Finally, the load itself: a fridge or pump cycles on and off, so use its average draw, not the rating plate, and an inverter draws a few watts just being switched on, which matters over long runtimes.

Treat the result as the centre of a range, not a promise: plan critical loads — medical devices, heating controls, a work laptop through an outage — at two-thirds of the calculated figure, and size the bank so the daily cycle stays shallow. A lead-acid bank cycled to 30 percent instead of 50 lasts roughly twice as many cycles; depth of discharge is the cheapest battery life you can buy.

A worked example

A 12V 100Ah lead-acid battery, an inverter at 85 percent, and a 200W load (a TV and lights, say). Stored energy: 1,200 Wh. Usable at 50 percent: 600 Wh. After the inverter: 510 Wh. Runtime: 510 / 200 = 2.55 hours — about 2 hours 33 minutes. Swap the battery for a 100Ah lithium of the same size: usable at 90 percent is 1,080 Wh, after a 90 percent efficient inverter 972 Wh, and a 100W load runs 9.72 hours. Same amp-hours on the label; nearly double the service, because the usable fraction and the efficiency, not the headline capacity, decide what you actually get.

Frequently asked questions

How long will a 100Ah battery run a 200W load?

It depends on the chemistry. A 12V 100Ah lead-acid battery used to its sensible 50 percent depth of discharge, through an 85 percent efficient inverter, delivers 510 usable watt-hours: 2.55 hours at 200W. A 100Ah lithium (LiFePO4) battery used to 90 percent through a 90 percent inverter delivers 972 Wh: 4.86 hours at 200W, or 9.72 hours at 100W. The amp-hour rating alone never answers the question.

Why can I only use half of a lead-acid battery?

Because deep discharge is what kills them. A lead-acid battery regularly emptied to zero may survive only 150 to 300 cycles; cycled to 50 percent it manages 500 to 800; kept to 30 percent, well over 1,000. The plates sulfate and shed material when deeply discharged. Lithium iron phosphate is built differently and tolerates 80 to 90 percent depth of discharge for thousands of cycles, which is why lithium banks are sized by their full capacity and lead-acid banks are not.

What does inverter efficiency do to runtime?

It multiplies straight through. An 85 percent efficient inverter delivers 85 of every 100 watt-hours to the load and turns the rest into heat, so runtime falls by 15 percent compared with a DC load of the same watts. Cheap inverters can be worse, especially at light loads, and every inverter draws standby power — 5 to 15 watts is common — which over a 10-hour night is 50 to 150 watt-hours gone before the load takes anything.

How do I combine batteries in a bank?

Add the energy, not just the amp-hours. In parallel, voltages stay and amp-hours add: two 12V 100Ah batteries make 12V 200Ah. In series, amp-hours stay and voltages add: the same pair makes 24V 100Ah. Either way the bank stores 2,400 watt-hours and runs a given load for the same time; enter the bank's wired voltage and capacity in the calculator. Keep batteries in a bank the same age, type and size so they share the work evenly.

How big a battery do I need for a full night?

Work backwards from the load. Add up the watt-hours the night actually uses — say a 60W fan for 10 hours (600 Wh), lights 40W for 5 hours (200 Wh), and a laptop 65W for 4 hours (260 Wh): 1,060 Wh delivered. Divide by inverter efficiency (0.9) and by the usable fraction (0.5 lead-acid, 0.9 lithium): you need about 2,356 Wh of lead-acid (roughly 12V 200Ah) or 1,309 Wh of lithium (about 12V 110Ah). Then add margin for ageing and cold.