Dew Point Calculator

In short: the dew point is the honest humidity number: the temperature at which the air would saturate and dew would form. At 30 C and 50% humidity it is 18.4 C — already on the sticky side. Enter the temperature and humidity (or work backwards to humidity from a known dew point) and this page gives the figure and how the air will actually feel.

The Magnus formula

Dew point is computed, not measured directly, and the standard computation is the Magnus formula in the coefficients published by Alduchov and Eskridge (1996), the pair NOAA uses: with a = 17.625 and b = 243.04 C, first form the intermediate value gamma = ln(RH/100) + aT/(b + T), where T is the air temperature in Celsius and RH the relative humidity in percent. Then the dew point is Td = b x gamma / (a - gamma). The formula is accurate to a few tenths of a degree across the whole weather range, from Arctic air to the tropics, which is why it sits inside weather stations, HVAC controllers and this page. The reverse calculation — humidity from temperature and dew point — is the same algebra run backwards: RH = 100 x exp(a·Td/(b + Td) - a·T/(b + T)), and the calculator’s second mode does exactly that.

Why meteorologists trust the dew point over relative humidity: RH is a ratio against a moving target. Air at 20 C and 65% humidity and air at 30 C and 50% humidity sound like different worlds, yet their dew points are 13.2 C and 18.4 C — the second air mass actually holds far more water, and the dew point says so immediately. RH also swings wildly through a day as temperature rises and falls, while the dew point barely moves unless the air mass itself changes. If you want to know whether tonight will feel muggy, whether dew will wet the tent, or whether a cold pipe will sweat, the dew point is the number that answers.

How the dew point feels

Dew pointHow the air feels
Below 10 C (50 F)Dry — skin and lips notice first.
10–13 C (50–55 F)Comfortable for most people.
13–16 C (55–61 F)Noticeably humid; warmth starts to cling.
16–18 C (61–65 F)Sticky — the edge of muggy.
18–21 C (65–70 F)Muggy; exercise feels harder.
21–24 C (70–75 F)Oppressive, tropical air.
24 C (75 F) and aboveSevere — the highest dew points on Earth.

The same number runs practical decisions far from the weather forecast. Condensation forms on any surface colder than the dew point — that is the whole science of sweating pipes, fogged windows, mould behind wardrobes and dew on grass, and it is why building engineers track dew point rather than humidity when they set ventilation. Pilots watch the gap between temperature and dew point: when the two meet, the air is saturated and fog or low cloud is forming. Gardeners and farmers read dew point for frost the other way — on a clear night the temperature falls toward the dew point and stalls there, because condensing dew releases heat; a dew point below zero (a frost point, strictly) is the frost warning. One number, four professions.

A worked example

Air temperature 30 C, relative humidity 50%. Gamma = ln(0.50) + (17.625 x 30) / (243.04 + 30) = -0.6931 + 1.9365 = 1.2434. Then Td = 243.04 x 1.2434 / (17.625 - 1.2434) = 302.2 / 16.38 = 18.4 C (65.2 F) — upper end of sticky, which matches how a 30-degree day at half humidity actually feels. The cross-check from the heat-index world: 90 F (32.2 C) at 70% humidity gives a dew point of 26.1 C (78.9 F), deep in the oppressive band — the same air whose heat index is 106 F. And the reverse mode: temperature 20 C with a dew point of 13.2 C returns a relative humidity of 65%, the pair the formula started from.

Frequently asked questions

How is the dew point calculated?

With the Magnus formula, using the Alduchov–Eskridge coefficients a = 17.625 and b = 243.04 C: gamma = ln(RH/100) + aT/(b + T), then dew point = b x gamma / (a - gamma), with T in Celsius. At 30 C and 50% humidity it gives 18.4 C. The formula is accurate to a few tenths of a degree across the normal weather range, which is why weather services and HVAC engineers use it rather than a lookup table.

Can the dew point be higher than the temperature?

No. The dew point is the temperature at which the existing water vapour would saturate the air, and saturation is exactly 100% humidity — which happens at the air temperature itself. So the dew point can equal the temperature (fog, saturated air) but never exceed it. If a calculator or a cheap sensor shows a dew point above the temperature, one of the two inputs is wrong; on this page the humidity mode will simply return 100% at that limit.

Which is the better comfort measure, dew point or relative humidity?

The dew point, and it is not close. Relative humidity compares the water in the air with the maximum that air could hold at its current temperature, so the same air reads 90% at dawn and 45% by afternoon without gaining or losing a drop. The dew point tracks the water itself: below about 13 C (55 F) air feels dry to comfortable, 18 C (65 F) is muggy, and 21 C (70 F) and above is oppressive — whatever the thermometer says. That stability is why forecasters quote it.

What is the frost point, and how is it different?

Below freezing, water vapour deposits as ice crystals rather than condensing as liquid, and the saturation temperature over ice is slightly higher than over supercooled water — that figure is the frost point. The Magnus formula in its common form gives the dew point over water; over ice the coefficients differ a little (a = 22.46, b = 272.62 C in one common set). The practical gap is under a degree in mild frosts, but it is why a -2 C night with a -1 C frost point grows hoar frost while the dew-point figure alone looks harmless.

Why do my windows and pipes get wet on some days?

Because their surfaces are colder than the dew point of the room air. Air touching a cold pane or pipe cools to the dew point, can hold no more vapour, and the excess condenses as liquid — the same physics as dew on grass, indoors. Raise the surface temperature (insulation, double glazing), lower the indoor dew point (ventilation, a dehumidifier), or both. The dew point tells you exactly how cold a surface can get before it starts to sweat: keep it above that number and the glass stays dry.

Related tools

Formula checked on 24 November 2026 (Magnus formula, Alduchov–Eskridge coefficients, as used by NOAA). Everything is calculated in your browser — nothing you type is sent anywhere.